Patient Exam Data Entry
Record: lasik_20260930_201913_a4fb9dceRecent Stored Assessments
| ID | Date | Age / CCT / RSB | ERSS | PTA | Action |
|---|---|---|---|---|---|
752_92b221f7 |
Sep 30, 20:17 | 30y / 550µm / 380µm | Low Risk | 30.9% | View | Print |
756_2ebe0fcc |
Sep 30, 20:17 | 30y / 550µm / 380µm | Low Risk | 30.9% | View | Print |
800_e40bb249 |
Sep 30, 20:18 | 30y / 550µm / 380µm | Low Risk | 30.9% | View | Print |
804_725ca1b2 |
Sep 30, 20:18 | 30y / 550µm / 380µm | Low Risk | 30.9% | View | Print |
913_a4fb9dce |
Sep 30, 20:19 | 28y / 540µm / 355µm | Low Risk | 34.3% | View | Print |
Assessment Result #lasik_20260930_201913_a4fb9dce
Open Printable Summary (PDF)
1. Percent Tissue Altered (PTA)
PASS
34.3% (0.3426)
Threshold: PTA < 0.40
Percent Tissue Altered is within safe limits (34.3% < 40.0%).
2. Randleman ERSS
Low Risk
2 points (Low Risk)
Topography: Normal
+0 pts
Rsb: 355 µm
+0 pts
Age: 28 yrs
+2 pts
Cct: 540 µm
+0 pts
Mrse: -4.38 D
+0 pts
Points Tier: 0–2 Low · 3 Moderate · ≥4 High Risk
Randleman ERSS score: 2 points (Low Risk).
3. Belin / Ambrósio Display Total D (BAD-D)
NOT PROVIDED
Optional Pentacam BAD-D was not entered. Screening proceeds with PTA, ERSS, and hard safety limits.
Threshold: Norm <1.6 · Susp 1.6–2.5 · High ≥2.6
Independent Binary Safety & Contraindication Checks
| Safety Criterion | Patient Value | Status | Clinical Interpretation |
|---|---|---|---|
| Residual Stromal Bed (≥ 300 µm) Ref: RSB ≥ 300 µm | 355 µm | PASS |
Residual stromal bed thickness is adequate.
|
| Central Corneal Thickness (≥ 500 µm) Ref: CCT ≥ 500 µm | 540 µm | PASS |
Pre-operative central corneal thickness is normal.
|
| Planned Ablation Depth (≤ 100 µm) Ref: Ablation depth ≤ 100 µm | 75 µm | PASS |
Planned ablation depth is within standard range.
|
| Percent Tissue Altered (PTA < 0.40) Ref: PTA < 0.40 | 34.3% (0.3426) | PASS |
Percent tissue altered is within safe limits.
|
| Corneal Topography (Normal pattern) Ref: Topography = Normal | Normal | PASS |
Topography is regular/symmetric.
|
| Mesopic Pupil Diameter (≤ 7.0 mm) Ref: Mesopic pupil ≤ 7.0 mm | 6.2 mm | PASS |
Mesopic pupil size is within normal treatment zone.
|
| Schirmer Test (≥ 4 mm/5 min) Ref: Schirmer ≥ 4 mm | 12 mm/5 min | PASS |
Basal tear production meets minimum threshold.
|
| Refraction Stability (≤ 0.50 D/year change) Ref: Refraction change ≤ 0.50 D/year | 0.25 D/yr | PASS |
Refraction demonstrates clinical stability over past 12 months.
|
| Clinical History Risk Factors (0 flagged) Ref: No clinical risk flags | None | PASS |