REFRACTIVE CDSS

LASIK Candidacy Screening

Biomechanical & Ectasia Risk Decision Support (Ophthalmology)
Ruleset v1.0 Mobile View ↗
Decision support only — does not replace surgeon judgment or full multimodal tomography review (Pentacam/Corvis ST).

Patient Exam Data Entry

Record: lasik_20260930_201804_725ca1b2
yrs
D
D
Calculated MRSE: -3.25 D (Sphere + Cyl / 2)
µm
µm
µm
µm
Auto-calculated: 380 µm (or enter manual override)
<1.6 Norm | 1.6–2.5 Susp | ≥2.6 High
mm
> 7.0 mm = Caution
mm/5m
< 4 mm = Caution
D/yr
> 0.50 D/yr = Caution (Unstable refraction)
Reset Form

Recent Stored Assessments

ID Date Age / CCT / RSB ERSS PTA Action
752_92b221f7 Sep 30, 20:17 30y / 550µm / 380µm Low Risk 30.9% View | Print
756_2ebe0fcc Sep 30, 20:17 30y / 550µm / 380µm Low Risk 30.9% View | Print
800_e40bb249 Sep 30, 20:18 30y / 550µm / 380µm Low Risk 30.9% View | Print
804_725ca1b2 Sep 30, 20:18 30y / 550µm / 380µm Low Risk 30.9% View | Print
913_a4fb9dce Sep 30, 20:19 28y / 540µm / 355µm Low Risk 34.3% View | Print
Assessment Result #lasik_20260930_201804_725ca1b2 Open Printable Summary (PDF)
1. Percent Tissue Altered (PTA) PASS
30.9% (0.3091)
Threshold: PTA < 0.40
Percent Tissue Altered is within safe limits (30.9% < 40.0%).
2. Randleman ERSS Low Risk
1 points (Low Risk)
Topography: Normal +0 pts
Rsb: 380 µm +0 pts
Age: 30 yrs +1 pts
Cct: 550 µm +0 pts
Mrse: -3.25 D +0 pts
Points Tier: 0–2 Low · 3 Moderate · ≥4 High Risk
Randleman ERSS score: 1 points (Low Risk).
3. Belin / Ambrósio Display Total D (BAD-D) NOT PROVIDED
Optional Pentacam BAD-D was not entered. Screening proceeds with PTA, ERSS, and hard safety limits.
Threshold: Norm <1.6 · Susp 1.6–2.5 · High ≥2.6

Independent Binary Safety & Contraindication Checks

Safety Criterion Patient Value Status Clinical Interpretation
Residual Stromal Bed (≥ 300 µm) Ref: RSB ≥ 300 µm 380 µm PASS
Residual stromal bed thickness is adequate.
Central Corneal Thickness (≥ 500 µm) Ref: CCT ≥ 500 µm 550 µm PASS
Pre-operative central corneal thickness is normal.
Planned Ablation Depth (≤ 100 µm) Ref: Ablation depth ≤ 100 µm 60 µm PASS
Planned ablation depth is within standard range.
Percent Tissue Altered (PTA < 0.40) Ref: PTA < 0.40 30.9% (0.3091) PASS
Percent tissue altered is within safe limits.
Corneal Topography (Normal pattern) Ref: Topography = Normal Normal PASS
Topography is regular/symmetric.
Mesopic Pupil Diameter (≤ 7.0 mm) Ref: Mesopic pupil ≤ 7.0 mm 6 mm PASS
Mesopic pupil size is within normal treatment zone.
Schirmer Test (≥ 4 mm/5 min) Ref: Schirmer ≥ 4 mm 15 mm/5 min PASS
Basal tear production meets minimum threshold.
Refraction Stability (≤ 0.50 D/year change) Ref: Refraction change ≤ 0.50 D/year 0 D/yr PASS
Refraction demonstrates clinical stability over past 12 months.
Clinical History Risk Factors (0 flagged) Ref: No clinical risk flags None PASS
No exclusionary systemic or ocular co-morbidities selected.